Portable X-ray NDT Equipment (Fixed
Direction)
Portable X-ray NDT Equipment (Circle
Direction)
Portable X-ray NDT Equipment (Ceramic Tube)
Movable (Fixed) X-ray NDT Equipment
Portable
X-ray NDT Equipment (Fixed Direction)
Q Serial of Carried,
Frequency conversion, gas insulation X-ray Detector
Special Features
►X-ray
generator small and light weight
►Easy
carrying and control
►Anode
to ground, force fan cooling
►Intermission
mode: 1:1 working and rest
►Radial
protection according to standard
►Insulation
medium: SF6
►Working
pressure: 0.35-0.50Mpa
►Remote
control upon request
Main Specification
Model |
XD-150 |
XD-225 |
XD-300 |
XD-350 |
XD-400 |
XD-450 |
Rated Tube
Volt (KV) |
150 |
225 |
300 |
350 |
400 |
450 |
Rated Tube
Current (mA) |
20(2) |
10(3) |
10(3) |
10(4) |
10(3) |
10(2) |
Radiation
Angle |
40(20) |
40(20) |
40(20) |
40(20) |
38(20) |
40(30) |
Focus Size(mm) |
55(1.0) |
55(1.0) |
55(3.0) |
55(3.0) |
70(1.0) |
55(2.5) |
Max
Penetration(mm) |
25(18) |
45(33) |
71(50) |
80(56) |
97(70) |
105(80) |
Portable
X-ray NDT Equipment (Circle Direction)
H Serial of Carried, Frequency conversion, gas insulation X-ray
Detector
Special Features
►X-ray
generator small and light weight
►Easy
carrying and control
►Anode
to ground, force fan cooling
►Intermission
mode: 1:1 working and rest
►Radial
protection according to standard
►Insulation
medium: SF6
►Working
pressure: 0.35-0.50Mpa
►Remote
control upon request
Main Specification
Model |
XG-300 |
XG-250 A/B |
XG=200 |
Power
Voltage |
220v±10%50HZ |
Tube Volt
Range(kv) |
170~300 |
150~250 |
100~200 |
Tube
Current(Ma) |
5 |
Radiation
Angle |
40+5° |
Focus Size(mm) |
23*13 |
20*20 |
20*20 |
Max
Penetration |
50 |
40 |
30 |
Generator
Weight (kg) |
36 |
A30B23 |
19 |
Generator
Size (mm) |
340*340*370 |
A 320*320*650
B 330*330*630 |
280*280*610 |
Portable
X-ray NDT Equipment (Ceramic Tube)
G Serial of Carried, Frequency conversion, gas insulation X-ray
Detector
Special Feature
►X-ray
generator small and light weight
►Easy
carrying and control
►Anode
to ground, force fan cooling
►Intermission
mode: 1:1 working and rest
►Radial
protection according to standard
►Insulation
medium: SF6
►Working
pressure: 0.35-0.50Mpa
►Remote
control upon request
Main Specification
Model |
XH-320 |
XH-300 |
XH-250 |
XH-200 |
XH-160 |
XH-100 |
Power
Voltage(KV) |
220v±10%50HZ |
Tube Volt
Range (kv) |
170~320 |
170~300 |
150~250 |
100~200 |
40~160 |
40~100 |
Tube
Current(mA) |
5 |
Radiation
Angle |
30+5°/25+5° |
Focus Size
(mm) |
1.0*5.0 |
1.0*2.3 |
1.0*2.4 |
1.0*3.5 |
1.0*3.5 |
1.0*3.5 |
Max
Penetration(mm) |
50/52 |
40/47 |
34/37 |
24/27 |
|
|
Generator
Weight(kg) |
41 |
40 |
32.5 |
20 |
16.5 |
8.5 |
Generator
Size(mm) |
340*340*840 |
340*340*840 |
320*320*730 |
270*270*660 |
215*620 |
135*555 |
Movable (Fixed) X-ray
NDT Equipment
D Serial of Carried, (fixed) X-ray Detector
Special Feature
►KV
preset
►LED
displays KV, MA, time and faults
►Automatic
training
►Automatic
recognize and inspect faults
►Timer
(0~98mins)
►Safety
chain lock
►Various
protection functions
►Digital
display of temperature and flux
Main Specification
Model |
XQ-320 |
XQ-300 |
XQ-250 |
XQ-200 |
XQ-160 |
XQ-100 |
Power
Voltage(KV) |
220v±10%50HZ |
Tube Volt
Range (kv) |
170~320 |
170~300 |
150~250 |
100~200 |
40~160 |
40~100 |
Tube
Current(mA) |
5 |
Radiation
Angle |
40+5° |
Focus Size
(mm) |
2.5*3.0 |
2.3*2.3 |
2.0*2.0 |
1.5*1.5 |
0.8*0.8 |
0.8*0.8 |
Max
Penetration(mm) |
55 |
50 |
40 |
30 |
19 |
8 |
Generator
Weight(kg) |
43 |
A43 B40 |
34 |
23.5 |
18.5 |
8.5 |
Generator
Size(mm) |
340*340*820 |
A 340*340*820
B 340*340*760 |
320*320*730 |
270*270*660 |
225*580 |
135*555 |
|